GDCY Impulse Voltage Test System (100kV-7200kV)
Impulse Voltage Test System is mainly used for carrying out full wave lightning impulse voltage test, chopping impulse test and switching impulse test on HV apparatus such as transformers, surge arrester, insulators, bushings, capacitors, and switches. It can generate standard lightning wave, switching wave, chopping wave with wide range voltage and energy.
-
Impulse Voltage Test System – High Voltage Test Instruments
GDCY series Impulse Voltage Generator can produce a wide range of voltage and energy to simulate waveform such as lightning impulse, lightning clipped wave, switching impulse and so on, enable to carry out various forms of impulse test for high voltage power equipment, cooperate with steepening device can carry out steep wave test on the insulator (insulator string).
-
GDCL-10kA Impulse Current Generator
The impulse current generator is mainly generating lightning impulse current 8/20μs, suitable for measuring residual voltage of surge arrester, varistors and other science research test.
-
GDSD-140 Dielectric Strength Test Set for Insulation Sample
GDSD-140 test device is mainly suitable for making breakdown strength and withstand voltage test of solid insulating materials (such as: plastic, rubber, laminated materials, films, resins, mica, ceramics, glass, insulating paint and other insulating materials and insulating parts) under power frequency voltage or DC voltage.
-
GDCR9300 Wireless Clamp Ammeter
GDCR9300 Wireless H/L Voltage Hook Type Current Meter break through the traditional structure, specially designed and manufactured for measuring high voltage current, the unique hook type opening mouth structure realizes the unimpeded measurement, and very convenient for field test. The meter is composed of special large-caliber hook type current meter with high voltage insulation rod, equipped with wireless receiver, which can receive the measured data within 100 meters straight line distance, current range: AC 0.00A-9999A. In low voltage lines below 600V, the line current can be measured directly by hook meter without insulation rod.
-
GDZRS-20B Three Phase DC Winding Resistance Tester
GDZRS-20B Three Phase DC Winding Resistance Tester is a new generation of rapid tester that integrates magnetization method testing, three-phase testing (Yn, Y, △) and degaussing functions. It is an ideal equipment for measuring the DC resistance of large power transformers. The screen adopts a large-screen high-resolution LCD, which is convenient for on-site use. All direct resistance test items can be completed with one connection. The test speed is fast, the accuracy is high, and the measuring range is wide.
-
GD9850A AC DC Insulation Tester
The AC DC Insulation Tester is electric safety device. It is neat and compact structure with mature technology. It is widely used for household appliance, instrument, and components etc.
-
GDPD-PTU PD Online Monitoring System for Oil Transformer
The aging and damage of the internal insulation of the transformer mostly starts from local discharge. The reason for local discharge is that the electric field is too concentrated at a certain point, or the electric field strength at a certain point is too large. At present, the main methods for detecting transformer local discharge faults are: UHF ultra-high frequency monitoring method, HFCT high-frequency pulse current local discharge measurement method (pulse current method), ultrasonic local discharge measurement method (ultrasonic method), and oil gas chromatography analysis method.
With the continuous expansion of the power grid, it is becoming increasingly important to improve the safe operation level of electrical equipment, carry out online monitoring of partial discharge of transformers, analyze the insulation status of transformers in combination with intelligent diagnostic expert systems, and determine the nature of insulation defects in a timely manner.
-
GDZRC-10U DC Winding Resistance Tester
The measurement of DC transformer resistance is a mandatory test item in transformer manufacturing of semi-finished products, finished products factory test, installation, handover test and preventive test of power department, which can effectively find the manufacturing defects of transformer coil material selection, welding, loose connection parts, missing strands, broken wires and other hidden dangers after operation.
GDZRC-10U DC Winding resistance tester is a rapid test equipment for measuring the DC resistance of transformers, transformers, generators and motors, and it is a replacement product of single and double arm Bridges.
-
GDCY-1000kV/100kJ Impulse Voltage Test System
Impulse Voltage Test System is mainly used to generate lightning impulse voltage, to research and check the ability of lightning impulse ability of electric equipment. It can generate standard lightning waveform and chopping waveform.
The system can be used for impulse voltage test and other scientific research on GIS, cable, insulators, air gap, bushing, transformers etc.
-
GDGK-601 Switch Power Supply Box
GDGK-601 switch operation power supply box is a special power supply designed for the detection and maintenance of high-voltage switch opening and closing coils and their operating mechanisms. It has the advantages of adjustable voltage, simple operation, small size, and easy to carry. It is an indispensable detection tool for high-voltage switch maintenance.
-
GDOP-I Oxygen Analyzer
The portable oxygen analyzer is a portable oxygen purity meter to meet the needs of industries such as power, petrochemical and chemical. The product can measure the purity of oxygen.
With microcontroller as the core, it uses a high-precision oxygen sensor as the measurement unit, which is suitable for measuring oxygen content in various working conditions. It has the characteristics of intelligence, high accuracy, fast response speed and good stability.